Publications – 2020

Chia-Han Chiang, Sang Min Won, Amy L. Orsborn, Ki Jun Yu, Michael Trumpis, Brinnae Bent, Charles Wang, Yeguang Xue, Seunghwan Min, Virginia Woods, Chunxiu Yu, Bong Hoon Kim1, Sung Bong Kim, Rizwan Huq, Jinghua Li, Kyung Jin Seo, Flavia Vitale, Andrew Richardson, Hui Fang, Yonggang Huang, Kenneth Shepard, Bijan Pesaran, John A. Rogers, Jonathan Viventi. Development of a neural interface for high-definition,
long-term recording in rodents and nonhuman primates
. DOI: 10.1126/scitranslmed.aay4682

Long-lasting, high-resolution neural interfaces that are ultrathin and flexible are essential for precise brain mapping and high-performance neuroprosthetic systems. Scaling to sample thousands of sites across large brain regions requires integrating powered electronics to multiplex many electrodes to a few external wires. However, existing multiplexed electrode arrays rely on encapsulation strategies that have limited implant lifetimes. Here, we developed a flexible, multiplexed electrode array, called “Neural Matrix,” that provides stable in vivo neural recordings in rodents and nonhuman primates. Neural Matrix lasts over a year and samples a centimeter-scale brain region using over a thousand channels. The long-lasting encapsulation (projected to last at least 6 years), scalable device design, and iterative in vivo optimization described here are essential components to overcoming current hurdles facing next-generation neural technologies.

Jordan Thimot, Kukjoo Kim, Chen Shi, and Kenneth L. Shepard. A 27-Mbps, 0.08-mm3 CMOS Transceiver with Simultaneous Near-field Power Transmission and Data Telemetry for Implantable Systems
Proceedings of the Custom Integrated Circuits Conference, 2020.

This paper describes an inductively powered 27-Mbps, 0.08-mm3 CMOS transceiver with integrated RF receivercoils for simultaneous two-way, near-field data telemetry andpower transmission for implantable systems. A four-coil inductivelink operates at a 27-MHz carrier for power and a 700-MHzcarrier for data telemetry with the antennae taking an area of only2 mm by 2 mm. Amplitude-shift-keying (ASK) modulation is usedfor data downlink at 6.6 kbps and load-shift keying (LSK)backscattering is used for data uplink at 27 Mbps. The transceiverconsumes 2.7 mW and can power a load consuming up to anadditional 1.5 mW. Implemented in a 0.18-um silicon-on-insulator(SOI) technology, post-processing steps are used to decrease chipthickness to approximately 15um, making the chip flexible with atissue-like form factor and removing the effects of the substrate oncoil performance. Power harvesting circuitry, including passiverectifier, voltage regulator, RF limiter, ASK and LSK modulator,clock generator, and digital controller are positioned adjacent tothe coils and limited to an area of 0.5 mm by 2mm. Completetransceiver functionality of the system has been achieved withoverall power transfer efficiency (PTE) of 1.04% through 1 mm oftissue phantom between reader and implant.

Y. Zhang, F. Cadoso, and K. L. Shepard, A 0.72 nW, 1 Sample/s Fully Integrated pH Sensor with 65.8 LSB/pH Sensitivity, Proceedings of the Symposium on VLSI Circuits (to appear).

C.Shi, T.Costa, J.Elloian, Y.Zhang, K.L. Shepard. A 0.065-mm3 Monolithically-integrated Ultrasonic Wireless Sensing Mote for Real-time Physiological Temperature Monitoring. DOI: 10.1109/TBCAS.2020.2971066

Accurate monitoring of physiological temperature is important for many biomedical applications, including monitoring of core body temperature, detecting tissue pathologies, and evaluating surgical procedures involving thermal treatment such as hyperthermia therapy and tissue ablation. Many of these applications can benefit from replacing external temperature probes with injectable wireless devices. Here we present such a device for real-time in vivo temperature monitoring that relies on “chip-as-system” integration. With an on-chip piezoelectric transducer and measuring only 380 μm ×× 300 μm × 570 μm, the 0.065-mm3 monolithic device, in the form of a mote, harvests ultrasound energy for power and transmits temperature data through acoustic backscattering. Containing a low-power temperature sensor implemented with a subthreshold oscillator and consuming 0.813 nW at 37 °C, the mote achieves line sensitivity of 0.088 °C/V, temperature error of +0.22/-0.28 °C, and a resolution of 0.0078 °C rms. A long-term measurement with the mote reveals an Allan deviation floor of <138.6 ppm, indicating the feasibility of using the mote for continuous physiological temperature monitoring.

J.Elloian, J.Sherman, T.Costa, C.Shi, and K.Shepard. Ablation of Piezoelectric Polyvinylidene Fluoride with a 193 nm Excimer Laser. DOI: 10.1116/1.5142494

The unique flexible and piezoelectric properties of polyvinylidene fluoride (PVDF) films would allow for new appli-cations for integrated bioelectronic devices. The use of these films has been precluded by the difficulty in machiningit into small, discrete features without damaging the properties of the material. The etching of piezoelectric PVDF bymeans of a 193 nm excimer laser is explored and characterized. Etch rates are shown for common laser fluence values,along with images of the quality of the cuts to provide the reader with an understanding of the compromise betweenetch rate and edge roughness.